(DISCONTINUED)CA-100Plus Color Analyzer
Konica Minolta (DISCONTINUED)CA-100Plus Color Analyzer

Click to Enlarge Thumbnails

Konica Minolta (DISCONTINUED)CA-100Plus Color Analyzer
Konica Minolta (DISCONTINUED)CA-100Plus Color Analyzer
Konica Minolta (DISCONTINUED)CA-100Plus Color Analyzer

View our latest version of this instrument, the CA-310 Color Analyzer.

The CA-100Plus is an extremely easy to use, highly accurate, and lightweight color analyzer which determines the brightness and whiteness of a light source.

The receptor head is simply held in front of the display light projection and measurement values are immediately displayed on the large screen. A rubber lip on the receptor head minimizes the effects of ambient light.

Measurements are displayed as luminance with standard color or color temperature values. Deviation from the reference value can also be shown on the screen. The display of the RGB values allows the user to quickly and easily balance whiteness levels of the source.

The CA-100Plus is also compatible with the CA-100 data and environment, making upgrading seamless.

PDFClick here for the (DISCONTINUED)CA-100Plus Brochure.

PDFClick here for the (DISCONTINUED)CA-100Plus Manual.


Features
  • Quick measurements  maximum speed of 20 cycles per second
  • Highly accurate  plus or minus 0.002 for white and plus or minus 0.004 for primary colors
  • Can measure low brightness  can measure brightness levels as low as 0.05cd/m2
  • Easy to upgrade  fully compatible with CA-100 data
  • Multiple sensors  up to 5 sensors can be connected using the expansion board, sold separately

Specifications
CA-100Plus (Measuring Probe) CA-100Plus (High Luminance Measuring Probe)
Detector
Silicon photocell Silicon photocell
Measurement diameter
Φ21mm Φ21mm
Display range Luminance
Chromaticity
0.01 to 1000cd/m2 0.01 to 2000cd/m2
Displayed in 4- or 3-digit values (selectable) Displayed in 4- or 3-digit values (selectable)
Luminance Measurement range
Accuracy (for white)*1
Repeatability*1
0.05 to 1000cd/m2 0.05 to 2000cd/m2
+-2%, +-1 digit of reading (Temperature: 23°C+-2°C, Relative humidity: (40+-10)%) +-2%, +-1 digit of reading (Temperature: 23°C+-2°C, Relative humidity: (40+-10)%)
0.05 to 1000cd/m20.2%+1 digit (2 sigma) 0.05 to 2000cd/m20.2%+1 digit (2 sigma)
Chromaticity Measurement range
Accuracy*1
Repeatability*1
0.05 to 1000cd/m2 0.05 to 2000cd/m2
0.05 to 0.19cd/m2 +-0.006 for white; 0.20 to 0.49cd/m2 +-0.004 for white; 0.50 to 1000cd/m2 +-0.003 for white; 40.00cd/m2 +-0.002 for white, +-0.004 for monochrome*2 0.05 to 0.09cd/m2 +-0.008 for white; 0.1 to 0.39cd/m2 +-0.006 for white; 0.40 to 0.99cd/m2 +-0.004 for white; 1.00 to 2000cd/m2 +-0.003 for white; 40.00cd/m2 +-0.002 for white, +-0.004 for monochrome*2
0.05 to 0.19cd/m2 0.006 (2 sigma;); 0.20 to 0.49cd/m2 0.002 (2 sigma;); 0.50 to 1000cd/m2 0.001 (2 sigma;) 0.05 to 0.09cd/m2 0.009 (2 sigma;); 0.1 to 0.39cd/m2 0.006 (2 sigma;); 0.40 to 0.99cd/m2 0.002 (2 sigma;); 1.00 to 2000cd/m2 0.001(2 sigma;)
Measurement speed*3 xyLv
0.05 to 0.99cd/m2
5 (4.5) meas./sec.*4 ; 1.00 to 1000cd/m2
20 (17) meas./sec.*4
0.05 to 1.99cd/m2
5 (4.5) meas./sec.*4 ;
2 to 2000cd/m2
20 (17) meas./sec.*4
Display Digital
Analog
xyLv, T ΔuvLv, RGB, XYZ, u;v;Lv xyLv, T ΔuvLv, RGB, XYZ, u;v;Lv
Δ x, Δ y, Δ Lv, R/G, B/G, Δ G, Δ R, B/R, G/R
SYNC mode
NTSC, PAL, EXT, UNIV, INT NTSC, PAL, EXT, UNIV, INT
Object under measurement
Vertical synchronous frequency: 40 to 200Hz Vertical synchronous frequency: 40 to 200Hz
Memory channels
100 100
Analyzer function
Standard function Standard function
Interface
USB (Version 1.1) or RS-232C (38,400bps or below) USB (Version 1.1) or RS-232C (38,400bps or below)
Multi-point measurement
Max. 5 points (Use 4-Probe Expansion Board CA-B04.) Max. 5 points (Use 4-Probe Expansion Board CA-B04.)
Operating temperature/humidity range
Temperature: 10 to 28° C; Relative humidity 70% or less with no condensation
Luminance change: +-2% +-1 digit of reading for white
Chromaticity change: +-0.002 for white, 0.006 for monochrome
(from reading of Konica Minolta's standard CRT*1, 40.00cd/m2, at 23° C, 40%
Temperature: 10 to 28°C; Relative humidity 70% or less with no condensation
Luminance change: +-2% +-1 digit of reading for white
Chromaticity change: +-0.002 for white, 0.006 for monochrome
(from reading of Konica Minolta's standard CRT*1, 40.00cd/m2, at 23°C, 40%
Storage temperature/humidity range
0 to 28°C: Relative humidity 70% or less with no condensation
28 to 40°: Relative humidity 40% or less with no condensation
0 to 28°C: Relative humidity 70% or less with no condensation
28 to 40°C: Relative humidity 40% or less with no condensation
Input voltage range
100 to 240V~, 50 to 60Hz, 50VA 100 to 240V~, 50 to 60Hz, 50VA
Dimensions (W x H x D) Main unit, Probe
340 x 127 x 216mm, Phi;45 x 142mm 340 x 127 x 216mm, Phi;45 x 142mm
Weight Main unit, Probe
3.58kg, 285g 3.58kg, 285g