The Soma spectroradiometer accurately measures the spectral irradiance of a solar simulator and determines its classification per the ASTM and JIS standards.
Request a Quote

The Soma Spectroradiometers are designed to accurately measure the spectral irradiance of sunlight. Used in conjunction with a solar simulator and included software, the light source can be tested and quantified.

This instrument utilizes a proprietary high-efficiency diffraction grating spectrometer and the S-2441C/2442C models add the ability to measure pulse-type solar simulators with an included trigger collector. This high-performance spectroradiometer is inexpensive and compact, making it ideal for all users.

The Soma S-2440C/2441C features a wavelength of 300~1100nm, 5nm resolution, and 2.5~1,000msec exposure time and the S-2442C decreases exposure time to 1~1,000msec. It operates off of Windows 2000/XP/Vista (32 bit) and has both spectral irradiance, ASTM and JIS output calculations.

Share
Soma Spectroradiometer Demo Image at Konica Minolta Sensing Americas, Inc. - A spectral irradiance measurement Instruments.

Multi-Function

The Soma Spectroradiometers can measure pulse-type, as well as non-pulse-type, solar simulators.

Ideal for all users

The Soma Spectroradiometers are inexpensive and compact.

Fast

The Soma Spectroradiometers provide quick measurements.

Calculations

The Soma Spectroradiometers calculate adherence to the ASTM and JIS standards.

Share
Model
S-2440C, S-2441C, S-2442C
Wavelength
300 ~ 1100nm
Slit Wavelength Width
5nm
Reflecting Diffuser
15H X 60W X 80Dmm / ø 40mm
Exposure Time
S-2440C, 2-2441C = 2.5 ~ 1,000 msec
2-2242C = 1 ~ 1,000 msec
Incidence Optics
Reflecting Diffuser 1m length optical fiber
Size
110(H) X 90(W) X 180(D) / 1.4kg
Trigger Unit
S-2440C = None
2-2441C, 2-2242C = Included
Operating System
Windows XP/Vista/7 32bit, 64bit (Japanese/English Version)
Interface
USB 2.0
Measuring Modes
S-2440C, 2-2441C = Normal Measuring, Trigger Signal, Repeat Measuring, Standard Light Source Measuring
2-2242C = All modes and an added Time resolving measuring mode
Data Format
CSV Text | 1nm data step
Measuring Item
Spectral Irradiance (µw / cm² / nm)

Classification of Spectral coincidence class:
IEC 60904-9 (ED-2) -2007, ASTM (Direct AM1.5, Global AM1.5) -2009
JIS C 8912-2011, JIS C 8933-2011, JIS C 8942-2009
Carrying Case
Included
Power
AC100 ~ 240V dedicated AC-DC adapter, Power for main body: DC12V 1A
Temperature and Humidity
10 - 35°C, Less than Relative Humidity 80% / Non-condensing