SpectraRad™
Miniature TE Cooled Spectral Irradiance Meter
The SpectraRad™ is a miniature TE Cooled Spectral Irradiance Meter designed for industrial and lab applications with a USB 2.0 interface.The SpectraRad™ is a miniature TE Cooled Spectral Irradiance Meter designed for industrial and lab applications with a USB 2.0 interface. The SpectraRad™ is equipped with a right angle, fiber-optically coupled cosine corrective lens, and is irradiance calibrated against a NIST traceable tungsten light source. BWSpec™ software is provided for characterization and measurement of many application lighting devices and systems. Standard software features include time line recording, data smoothing, illuminance (lux), chromaticity, color temperature, externally triggered pulsed light capturing, and other data-handling functions. This spectral irradiance meter is ideal for lamp and LED characterization, color analysis, solar studies, photostability testing, photobiology and photochemistry.
Custom configurations available upon request.
Advantages
The SpectraRad™ offers significant improvements over traditional filter based technology instruments. Filter based instruments have been desired for certain properties (cost, speed and portability) but lack the resolution to accurately describe the spectral characteristics of a light source. Filter based instruments only acquire average three data points across the entire spectrum of light to yield colorimetric values. This is accomplished by the use of filters corresponding to the normal human eye response. These filters can only be manufactured to a certain degree of accuracy. Due to these facts, filter based meters are susceptible to errors because of the deviation of the filter response from the ideal human eye response and the lack of resolution needed to accurately describe narrow bandwidth light sources.
The SpectraRad™ avoids these problems at a comparable cost, higher speed and small footprint because it acquires hundreds of data points across the visible spectrum. The 2048 pixel linear CCD array provides the precision required to accurately measure narrow bandwidth light sources or LEDs. Having multiple sensors also enables the unit to report spectral data and display spectral graphs, making it the ideal instrument for evaluating LEDs, which is today’s dominant light source.
Optical
| Spectral Range | 380nm - 750nm, 350-1050nm, 250-800nm, 750-1050nm, and custom configurations upon request |
|---|---|
| Spectral Resolution | <1.5nm |
| Irradiance Range | 25 nW/cm2/nm - 4 mW/cm2/nm |
| Detector Type | 2048 element linear silicon CCD array |
Electrical
| Detector Type |
Response Enhanced 2048 element linear silicon CCD array |
|---|---|
| External Trigger | Aux Port |
| Computer Interface | USB 2.0 / 1.1 |
| Data Transfer Speed | Up to 180 spectra per second via USB 2.0 |
| DC Power Input | 5V DC < 1.5 Amps |
Software
| Integration Time |
5 ~ 65,535ms x multiplier |
|---|---|
| Operating Systems | Windows: XP, Vista (32-bit), 7 (32-bit) |
| Environmental Operating Temperature | 15°C - 35°C |
| Operational Relative Humidity | 85% Noncon |
Specifications are subject to change without notice.
No accessories for this product.
Transmittance / Absorption
Example System: Glacier X, light source, Cuvette holder, 2 fibers, PC Software.
Application: The measurement of transmittance and absorbance of a sample liquid such as Juice. This example set up allows the measurements in the UV range at an affordable price.
Transmittance via Immersion Probe
Example System: Cypher H spectrometer, immersion probe, light source, fibers, pc software
Application: measurements using an immersion probe are ideal for the spectral analysis of solutions with low transparency.
LED Measurement
Example System: Quest X spectrometer, integrating sphere, fibers, pc software
Application: spectral, light output, and color characterization of LED's. Ideal for quality control and R&D applications where speed and cost effective measurements are required.
Fluorescence Measurement
Example System: Glacier X spectrometer, laser excitation, dichroic filter, coupling lens, pc software.
Application: Using laser light the measurement of weak fluorescence of the sample is possible. The Glacier X spectrometer is also cooled allowing noise suppression in low light measurements over longer periods of time.
Environmental Monitoring
Example System: i-trometer spectrometer, collimator lens, fiber, pc software.
Application: By using a high sensitivity and high dynamic range spectrometer environmental monitoring various parameters is achievable. For example we have used our system to analyze the spectral characteristics of emissions from volcanoes.
UV/Vis Spectroscopy for HPLC
Example System: i-trometer spectrometer, flow cell, UV light source, liquid sample transmission system, fibers, pc software
Application: Equipping your high performance liquid chromatography system with UV/Vis spectroscopic data.
Reflection Measurements
Example System: Cypher H spectrometer, reflectance probe, fibers, light source, pc software.
Application: Reflectance spectrum of materials can be characterized, for example color in-line monitoring, general color measurement, and general spectroscopy of materials which reflect light.
Spectral Irradiance Measurements
Example System: SpectraRad xpress (shown here) or SpectraRad featured in SPIE article, pc software.
Application: A system for the fast and easy spectral characterization of light sources, including intensity and color measurement.