FD-9 Auto Scan Spectrophotometer
Konica Minolta FD-9 Auto Scan Spectrophotometer

Click to Enlarge Thumbnails

Konica Minolta FD-9 Auto Scan Spectrophotometer
Konica Minolta FD-9 Auto Scan Spectrophotometer
Konica Minolta FD-9 Auto Scan Spectrophotometer
Konica Minolta CM-5 Spectrophotometer

The key to success for the modern professional print business is automation and accuracy. The Konica Minolta FD-9 Auto Scan Spectrophotometer is the ideal tool for print color management, combining speed, accuracy, ease-of-use and versatility.

The FD-9 reads 1,500 patches in just 4 minutes and within one single scan users obtain data for M0, M1 and M2, conforming to ISO13655:2009 and offering improved certainty of colors and OBA. The FD-9 uses a free-format-function enabling it to measure virtually every chart that might be used to calibrate printers and create profiles. Making it even easier to use is it has a full color LCD screen which provides enhanced user operation. It also features both USB and Ethernet connectivity enabling you to easily share one FD-9 between multiple machines. With the unique integrated image scanner, it enables automatic chart alignment and can read QR codes for fully automated sheet and chart identification. Similar to the groundbreaking FD-7, the FD-9 features built-in wavelength calibration and temperature drift compensation, maximizing day to day accuracy and reliability. FD-9 also includes FD-S2w measurement utility software as a standard accessory. The software enables easy measurement of color charts with or without definition file.

The optional automatic sheet feeder enables continuous measurement which is perfect for users who have to measure dozens of sheets every day. The automatic sheet feeder enables up to 100 sheets to be pre-loaded and measured with minimal user input. Combined with the QR code reader function, the measurement results can be automatically linked to the printed sheet.

PDFClick here for the FD-9 Brochure.

PDFClick here for the FD-9 Manual.


Features
  • Ultra-high-speed spot measurements
  • Built-in wavelength calibration and temperature drift compensation
  • Free format function - No need for any special format for the chart recognition
  • USB and Ethernet connectivity enabling sharing amongst multiple machines
  • Includes FD-S2w measurement utility software
  • Optional automatic sheet feeder enables continuous measurement
  • Displayed languages: German, French, Spanish, Italian, Polish, Russian, Portuguese, English, Japanese, and Simplified Chinese
  • Maximum paper length extends to 1500mm
Software

The FD-9 is recognized as the ultimate automated chart reader and supported by a growing number of software solutions.

Direct Support

  • basICColor catch 5
  • CGS ORIS Press Matcher // Web
  • CGS ORIS Color Tuner // Web
  • CGS ORIS Certified // Web
  • ColorLogic ColorAnt 4
  • Creo Color Servers
  • Durst Workflow-Label
  • EFI Fiery Digital Frontends
  • EFI Color Profiler Suite
  • Heidelberg Color Toolbox 17
  • Konica Minolta ColorCentro
  • Konica Minolta ColorCare Suite
  • Konica Minolta ColorCare Server
  • Konica Minolta Falbard Aqua
  • Konica Minolta FD-s2w
  • ONYX PosterShop, ProductionHouse and Thrive 12.1 and higher
  • CHROMiX Curve4

Partly supported

Dedicated FD-9 charts are available. Measurement values are imported from FD-s2w.

  • Caldera V11
  • systemata Inkjet.Perfect
  • systemata Laser.Perfect
  • systemata Tif.Perfect CTP/CTF
  • systemata PDF.Perfect

Supported via file import

Measurements from FD-s2w can be imported into every software supporting the CGATS (ISO 28178) file format for characterization data e.g.

  • basICColor CMYKick, dropRGB, print, Devil, ImProve
  • ColorLogic CoPrA, ColorAnt < Version 4

Company names and product names mentioned here are the registered trademarks or trademarks of their respective companies.


    Specifications
    Model Auto Scan Spectrophotometer FD-9
    Illumination/viewing system 45°a: 0° (annular illumination) *1>
    Conforms to CIE No. 15, ISO 7724/1, DIN 5033 Teil 7, ASTM E 1164, and JIS Z 8722 Condition a for reflectance measurements
    Spectral separation device Concave grating
    Wavelength range 380 nm to 730 nm
    Wavelength pitch 10 nm
    Half bandwidth Approx. 10 nm
    Measurement area Approx Φ3 mm
    Light source LED
    Measurement range Reflectance: 0 to 150%
    Short-term repeatability Within σΔE00 0.05
    (When white plate is measured 30 times at 10-second intervals after white calibration has been performed)
    Inter-instrument agreement Within ΔE00 0.3 (Average of 12 BCRA Series II color tiles compared to values measured with a master body under Konica Minolta standard conditions)
    Measurement time Approx 4 min./1,500 patch
    (Under Konica Minolta measurement condition*3)
    Output data Spectral reflectance data
    Measurement conditions*2 Corresponding to ISO 13655 Measurement Conditions M0 (CIE Illuminant A), M1 (CIE Illuminant D50), and M2 (illumination with UV-cut filter); User-defined illuminant
    Sample backing Corresponding to ISO 13655 Standard white backing
    Interface USB2.0, 100Base-TX
    Power Included AC adapter: Input: AC 100 to 240V 50-60Hz; Output: DC 24V 5A
    Dimensions
    (W × D × H)
    716×251×159mm(Body only)
    601×1158×245mm(Auto sheet feeder only)
    Weight 10.5kg(Body only)
    Operating temperature/ humidity range 10 to 35°C, 30 to 85% relative humidity with no condensation
    Storage temperature/humidity range 0 to 45°C, 0 to 85% relative humidity with no condensation
    Standard accessories AC adapter,USB cable,Measurement Utility software FD-S2w
    Optional accessory Auto sheet feeder
    Measurment chart conditions
    Paper width 45 to 330mm
    Paper length 170 to 1500mm
    Paper thickness 0.05 to 0.45mm
    Patch size 6x6mm or larger
    Maximum number of patches 1394 (A4)
    2928 (A3)
    Margins (minimum) Leading: 23mm; Trailing; 33 mm; Left/right sides: 4 mm each

    Specifications are subject to change without notice.
    *1 Illumination for wavelengths under 400nm is unidirectional.
    *2 M0,M1, and M2 are measurement conditions described in "4.2.2 Illumination requirement and measurement conditions" in ISO 13655.
    *3 Paper size : A3 , patch size : 6mm x 6mm, patch arrangement : 32 rows x 47 columns
    *4 Even if paper size is within the ranges specified, some charts may not be measured.

    Main specifications of the Software FD-S2w
    Operating Environment OS Windows7 /Windows8.1 / Windows10 / MacO X 10.9 10.10
    CPU 1 GHz or higher
    Memory 2 GB or more (64 bit)
    Hard disk 8GB recommended
    Display Display unit capable showing at least 1024 x 768 dots
    Interface USB2.0, 100Base-TX
    Compatible instruments FD-9 / FD-7 / CL-500A (Only reading of user-defined illuminant data for FD-7 and CL-500)
    Major functions Create chart ; Measurement of chart ; Display Measurement values ; Export Measurement data file ; Create QR code
    Measurement values Spectral reflectance data, colorimetric values
    Measurement conditions Corresponding to ISO 13655 Measurement Conditions M0 (CIE Illuminant A), M1 (CIE Illuminant D50), and M2 (illumination with UV-cut filter); User-defined illuminant
    Illuminants A, C, D50, D65, ID50, ID65, F2, F6, F7, F8, F9, F10, F11, F12, A+UV cut, User-defined illuminant
    Observers 2° Standard Observer, 10° Standard Observer
    Color spaces L*a*b*, L*C*h, XYZ
    Display languages English, German, French, Spanish, Japanese, Chinese (Simplified)
    Exported data format CxF3: ISO17972-1:2015 ; CGATS: ISO28178:2009 (ANSI CGATS-17) ; FD-S2w Original Format (csv/tsv)

    Included Accessories
    AC Adapter body
    AC Adapter body
    Buy Now >
    AC Cable
    AC Cable
    Buy Now >

    Suggested Accessories
    Auto sheet feeder
    Auto sheet feeder
    Buy Now >
    AC Power Cord(100-120V・3P)
    AC Power Cord(100-120V・3P)
    Buy Now >
    USB Cable
    USB Cable
    Buy Now >
    Calibration certificate
    Calibration certificate
    Buy Now >
    Quick Links

    © 2006-2017 Konica Minolta Sensing Americas, Inc.

    Designed and Maintained by Giovatto