CS-200 Color and Luminance Meter


Click to Enlarge Thumbnails

Click Here to Watch Video

CS-200 Color and Luminance Meter

The CS-200 is designed to measure both luminance and chromaticity with high accuracy. It is a low cost option that is easy to use and features a new auto mode for determining measurement speed according the luminance of the subject being measured.

It can measure any light source over a wide range of luminance levels from 0.01 cd/m2 to 20,000,000 cd/m2. The selectable measuring angle feature enables the user to select the optimum angle of 1°, 0.2°, or 0.1° based on the application.

The CS-200 is lightweight and battery powered for optimum portability. Data management software CS-S10w is included as a standard accessory. The software enables the user to easily view and manage measurement data. Up to 101 measurement values can be stored in addition to 20 reference values.

Existing Customer?

If you're looking for service support or help with calibration then complete a service request form and we'll get right back to you

Features

  • Portable, lightweight, compact and battery powered
  • Easy to use and affordable
  • Selectable measuring range
  • Measure both luminance and chromaticity
  • Auto mode to determine measurement speed
  • Can be used for both low and high luminance
  • Measuring angle switching
  • CS-S10w data management software included as a standard accessory
  • Eligible ISO 17025 Certification

Specifications

Model CS-200 Luminance Color Meter
Measurement range 0.01 – 200,000 cd/m² (Measuring angle 1 °)
0.01 – 5,000,000 cd/m² (Measuring angle 0.2 °)
0.01 – 20,000,000 cd/m² (Measuring angle 0.1 °)
Accuracy (Measuring angle 1°) *1
(Standard Illuminant A;
Temperature: 23 degC+-2 degC, Relative humidity: 65% max.)
150 cd/m² ( for Illuminant A ) : Lv +-2 % +-1digit ; xy +-0.002
0.01-0.5 cd/m² ( for Illuminant A ) : Lv +-0.02cd/m² +-1digit ;
0.5-1 cd/m² ( for Illuminant A ) : Lv +-0.02 cd/m² +-1digit ; xy +-0.007
1-10 cd/m² ( for Illuminant A ) : Lv +-2 % +-1digit ; xy +-0.004
10-200,000 cd/m² ( for Illuminant A) : Lv +-2 % +-1digit ; xy +-0.003
5000 cd/m² ( for Illuminant A ) : color filter (R, G, B) ; xy +-0.006
Light source at 5000 cd/m² + color filter (R, G, B)
Repeatability (Measuring angle 1°) *2 (Standard Illuminant A) 0.01-1 cd/m² ( for Illuminant A ) : Lv +-0.01 cd/m² +-1digit ; — (2σ/Auto)
1-2 cd/m² ( for Illuminant A ) : Lv +-0.5 % +-1digit ; xy 0.002 (2σ/Auto)
2-4 cd/m² ( for Illuminant A ) : Lv +-0.5 % +-1digit ; xy 0.001 (2σ/Auto) xy +-0.007
4-8 cd/m² ( for Illuminant A ) : Lv +-0.5 % +-1digit ; xy 0.0005 (2σ/Auto) xy +-0.004
8-200,000 cd/m² ( for Illuminant A ) : Lv +-0.1% +-1digit ; xy 0.0004 ((2σ/Auto) xy +-0.003
Measurement time Automatic setting between 1s and 60s (AUTO); Automatic setting to 1s or 3s (LTD. AUTO)
0.5 sec / meas. (Super-FAST) 1 sec / meas.(FAST)3 sec / meas. (SLOW) 12 sec / meas. (Super-SLOW)
Measurement method Spectral method, Grating + linear photo diode array
Measuring angle 1°, 0.2°, 0.1°(switchable)
Minimum measuring area 0.5 mm
0.1 mm (close up lens)
Minimum measuring distance 296 mm (Distance from front edge of metal lens barrel)
Observer 2/10°
Color space Lv x y, Lv u’ v’, Lv T Delta;uv, XYZ, dominant wavelength
Measurement synchronization setting range Vertical synchronization frequency : 40.00 to 200.00Hz
Interface USB 1.1
Power source AC adapter or 4 AA-Size Batteries
Battery life Approx. 3 hours (continuous measurement / Fast mode / AA-size alkaline cells)
Size 95 mm (W) x 127 mm (H) x 330 mm (L)
Weight 1.8 kg (without battery)
Operating temperature/humidity range 0°C to 40°, relative humidity 85% or less (at 35°) with no condensation
Storage temperature /humidity range 0°Cto 45°C,relative humidity 85% or less (at 35°C)with no condensation
*1 23°C+-2°C Lv = 0.01-10 cd/m², SLOW, average of 30 measurements Lv = 10 cd/m² and higher, SLOW, average of 10 measurements
*2 At 0.2°measuring angle, the amount of received light is approx. 1/25 of that for 1°.
Therefore, the repeatability becomes the same as that for 1 degwith 25 times lower luminance.
At 0.1°measuring angle, the amount of received light is approx. 1/100 of that for 1°.
Therefore, the repeatability becomes the same as that for 1 degwith 100 times lower luminance.

Included Accessories

AC Adapter (120 V)
Buy Now

CS-A1 ND Eyepiece Filter CS-A27
Buy Now

CS-A24 Holding Cap
Buy Now

CS-S10W Software Prof. Vers. (USB) 1.6
Buy Now

IF-A17 USB Cable (2m)
Buy Now

Lens Cap
Buy Now

Suggested Accessories

293 ALU Tripod (3S) (MK293A3-D3Q2)
Buy Now

CS-A23 Soft Case
Buy Now

CS-A24 Holding Cap
Buy Now

CS-A26 Step-up Ring (40.5-55mm)
Buy Now

CS-A6 ND Filter (1/10)
Buy Now

CS-S10W Software Prof. Vers. (USB) 1.6
Buy Now

Close-Up Lens #122
Buy Now

Close-up Lens #107
Buy Now

Custom Illuminance Adapter for CS-200
Buy Now

ND Filter (1/100) CS-A7
Buy Now

White Calibration Plate with Calibration Data
Buy Now

Privacy Preference Center