CA-100Plus Color Analyzer (Discontinued)
Click to Enlarge Thumbnails
View our latest version of this instrument, the CA-410.
The CA-100Plus is an extremely easy to use, highly accurate, and lightweight color analyzer which determines the brightness and whiteness of a light source.
The receptor head is simply held in front of the display light projection and measurement values are immediately displayed on the large screen. A rubber lip on the receptor head minimizes the effects of ambient light.
Measurements are displayed as luminance with standard color or color temperature values. Deviation from the reference value can also be shown on the screen. The display of the RGB values allows the user to quickly and easily balance whiteness levels of the source.
The CA-100Plus is also compatible with the CA-100 data and environment, making upgrading seamless.
Features
- Quick measurements – maximum speed of 20 cycles per second
- Highly accurate – plus or minus 0.002 for white and plus or minus 0.004 for primary colors
- Can measure low brightness – can measure brightness levels as low as 0.05cd/m2
- Easy to upgrade – fully compatible with CA-100 data
- Multiple sensors – up to 5 sensors can be connected using the expansion board, sold separately
Specifications
CA-100Plus (Measuring Probe) | CA-100Plus (High Luminance Measuring Probe) |
Detector
Silicon photocell | Silicon photocell |
Measurement diameter
Φ21mm | Φ21mm |
Display range | Luminance |
Chromaticity |
0.01 to 1000cd/m2 | 0.01 to 2000cd/m2 |
Displayed in 4- or 3-digit values (selectable) | Displayed in 4- or 3-digit values (selectable) |
Luminance | Measurement range |
Accuracy (for white)*1 | |
Repeatability*1 |
0.05 to 1000cd/m2 | 0.05 to 2000cd/m2 |
+-2%, +-1 digit of reading (Temperature: 23°C+-2°C, Relative humidity: (40+-10)%) | +-2%, +-1 digit of reading (Temperature: 23°C+-2°C, Relative humidity: (40+-10)%) |
0.05 to 1000cd/m20.2%+1 digit (2 sigma) | 0.05 to 2000cd/m20.2%+1 digit (2 sigma) |
Chromaticity | Measurement range |
Accuracy*1 | |
Repeatability*1 |
0.05 to 1000cd/m2 | 0.05 to 2000cd/m2 |
0.05 to 0.19cd/m2 +-0.006 for white; 0.20 to 0.49cd/m2 +-0.004 for white; 0.50 to 1000cd/m2 +-0.003 for white; 40.00cd/m2 +-0.002 for white, +-0.004 for monochrome*2 | 0.05 to 0.09cd/m2 +-0.008 for white; 0.1 to 0.39cd/m2 +-0.006 for white; 0.40 to 0.99cd/m2 +-0.004 for white; 1.00 to 2000cd/m2 +-0.003 for white; 40.00cd/m2 +-0.002 for white, +-0.004 for monochrome*2 |
0.05 to 0.19cd/m2 0.006 (2 sigma;); 0.20 to 0.49cd/m2 0.002 (2 sigma;); 0.50 to 1000cd/m2 0.001 (2 sigma;) | 0.05 to 0.09cd/m2 0.009 (2 sigma;); 0.1 to 0.39cd/m2 0.006 (2 sigma;); 0.40 to 0.99cd/m2 0.002 (2 sigma;); 1.00 to 2000cd/m2 0.001(2 sigma;) |
Measurement speed*3 | xyLv |
0.05 to 0.99cd/m2 5 (4.5) meas./sec.*4 ; 1.00 to 1000cd/m2 20 (17) meas./sec.*4 |
0.05 to 1.99cd/m2 5 (4.5) meas./sec.*4 ; 2 to 2000cd/m2 20 (17) meas./sec.*4 |
Display | Digital |
Analog |
xyLv, T ΔuvLv, RGB, XYZ, u;v;Lv | xyLv, T ΔuvLv, RGB, XYZ, u;v;Lv |
Δ x, Δ y, Δ Lv, R/G, B/G, Δ G, Δ R, B/R, G/R |
SYNC mode
NTSC, PAL, EXT, UNIV, INT | NTSC, PAL, EXT, UNIV, INT |
Object under measurement
Vertical synchronous frequency: 40 to 200Hz | Vertical synchronous frequency: 40 to 200Hz |
Memory channels
100 | 100 |
Analyzer function
Standard function | Standard function |
Interface
USB (Version 1.1) or RS-232C (38,400bps or below) | USB (Version 1.1) or RS-232C (38,400bps or below) |
Multi-point measurement
Max. 5 points (Use 4-Probe Expansion Board CA-B04.) | Max. 5 points (Use 4-Probe Expansion Board CA-B04.) |
Operating temperature/humidity range
Temperature: 10 to 28° C; Relative humidity 70% or less with no condensation Luminance change: +-2% +-1 digit of reading for white Chromaticity change: +-0.002 for white, 0.006 for monochrome (from reading of Konica Minolta’s standard CRT*1, 40.00cd/m2, at 23° C, 40% |
Temperature: 10 to 28°C; Relative humidity 70% or less with no condensation Luminance change: +-2% +-1 digit of reading for white Chromaticity change: +-0.002 for white, 0.006 for monochrome (from reading of Konica Minolta’s standard CRT*1, 40.00cd/m2, at 23°C, 40% |
Storage temperature/humidity range
0 to 28°C: Relative humidity 70% or less with no condensation 28 to 40°: Relative humidity 40% or less with no condensation |
0 to 28°C: Relative humidity 70% or less with no condensation 28 to 40°C: Relative humidity 40% or less with no condensation |
Input voltage range
100 to 240V~, 50 to 60Hz, 50VA | 100 to 240V~, 50 to 60Hz, 50VA |
Dimensions (W x H x D) | Main unit, Probe |
340 x 127 x 216mm, Phi;45 x 142mm | 340 x 127 x 216mm, Phi;45 x 142mm |
Weight | Main unit, Probe |
3.58kg, 285g | 3.58kg, 285g |