CA-510 Display Color Analyzer
We developed the CA-510 to meet the increasing demands of modern display technologies. As OLED, micro-LED, and HDR displays advance, so do the requirements for accurate and efficient measurement. Building on our previous-generation analyzers, the CA-510 expands luminance and chromaticity ranges, improves low-luminance speed, and enhances waveform and flicker analysis. The CA-510 is suited to various measurement geometries, supporting both R&D and production. We optimized the CA-510 for applications requiring a compact measurement area and reliable low-luminance performance, making it well-suited for OLED and micro-LED evaluation.
Compact Probe for High-Precision Measurement
The CA-510 features a Ø10mm measurement area and a ±15° acceptance angle, optimized for capturing light from displays with wide angular emission characteristics. This configuration improves sensitivity in low-luminance regions, making the CA-510 well-suited for evaluating high-contrast OLED panels and dynamic drive systems.
Expanded Measurement Range
The CA-510 supports an accuracy-guaranteed luminance range of 0.0002 to 20,000 cd/m² and a chromaticity range of 0.002 to 20,000 cd/m². This expanded dynamic range enables reliable measurement across a broad range of brightness levels, from deep blacks to peak luminance.
Fast and Repeatable Low-Luminance Measurement
Measurement speed is critical in both R&D and production environments. The CA-510 achieves 1-second measurements at 0.0002 cd/m² in AUTO mode, reducing takt time and supporting efficient gamma adjustment and inspection workflows.
Advanced Flicker and Waveform Analysis
The CA-510 supports multiple flicker evaluation methods, including JEITA, VESA, FMA, and VRR-Flicker, the latter developed by Konica Minolta to address limitations in conventional FFT-based approaches. With a sampling frequency of up to 200 kHz, the CA-510 enables detailed waveform analysis, including color waveform output (XYZ), which is valuable for assessing emission timing and RGB element behavior.
Software Integration and Automation
The CA-510 is compatible with the CA-S40 Ver. 2.2 and CA-SDK2. These tools offer complete control over measurement functions, data visualization, and integration into automated systems. Features such as multi-channel calibration, residual light suppression, and customizable AUTO mode enhance measurement reliability and adaptability.
Applications
The CA-510 is designed for use in:
- OLED and micro-LED display development
- Smartphone and automotive display evaluation
- Production line optimization
- Visual quality assurance and inspection
Existing Customer?
If you're looking for service support, help with calibration or need technical support assistance then complete the Service or Tech Support Form and we'll get right back to you
Features
- Expanded Measurement Range: wider range of measurement accuracy and repeatability than the conventional Display Color Analyzer series. Luminance: 0.0002 to 20,000 cd/m² – Chromaticity: 0.002 to 20,000 cd/m²
- Faster Low-Luminance Measurement: 1 sec measurement at 0.0002 cd/m² in AUTO mode
- Waveform Measurement Enhancements: Sampling frequency: Up to 200 kHz, changeable Waveform luminance range: 0.2 to 20,000 cd/m²
- Software Integration: Compatible with CA-S40 Ver.2.2 and CA-SDK2, downloadable free from Konica Minolta’s website
- New ‘Variable Refresh Rate (VRR) flicker’ measurement (the latest index in flicker evaluation), in addition to the high-performance flicker measurement function using the JEITA, VESA, and FMA methods as provided by the conventional Display Color Analyzer series.
Specifications
| CA-510 | ||||
| Measurement area | Ø 10 mm | |||
| Acceptance angle | ± 15° | |||
| Accuracy guaranteed measurement distance | 30 ± 5 mm | |||
| Luminance | Accuracy guaranteed luminance range *7 | 0.0002 to 20,000 cd/m2 | ||
| Accuracy (for white)*1, *3 | > 0.0001 cd/m2 | — | ||
| > 0.0002 cd/m2 | ± 9 % | |||
| > 0.0005 cd/m2 | ± 3.5 % | |||
| > 0.001 cd/m2 | ± 3 % | |||
| > 0.01 cd/m2 | ± 2 % | |||
| > 0.1 cd/m2 | ± 1.5 % | |||
| Repeatability (2σ)*1 | AUTO | > 0.0001 cd/m2 | — | |
| > 0.0002 cd/m2 | 10 % | |||
| > 0.0005 cd/m2 | 3 % | |||
| > 0.001 cd/m2 | 2 % | |||
| > 0.01 cd/m2 | 0.35 % | |||
| > 0.1 cd/m2 | 0.12 % | |||
| > 1 cd/m2 | 0.10 % | |||
| Chromaticity | Accuracy guaranteed luminance range *7 | 0.002 to 20,000 cd/m2 | ||
| Accuracy (for white)*1, *3 | > 0.001 cd/m2 | — | ||
| > 0.002 cd/m2 | ± 0.003 | |||
| > 0.01 cd/m2 | ± 0.002 | |||
| Repeatability (2σ)*1 | AUTO | > 0.001 cd/m2 | — | |
| > 0.002 cd/m2 | 0.0030 | |||
| > 0.01 cd/m2 | 0.0012 | |||
| > 0.1 cd/m2 | 0.0005 | |||
| > 1 cd/m2 | 0.0003 | |||
| > 10 cd/m2 | 0.0002 | |||
| Flicker (Contrast) | Flicker *6 | Measurement luminance range*7 | 1 to 20,000 cd/m2 | |
| Measurement target (Flicker frequency) | 0.25 to 65 Hz | |||
| Accuracy | 30 Hz, AC/DC 10% sine wave | ± 0.3 % | ||
| 60 Hz, AC/DC 10% sine wave | ± 0.3 % | |||
| Repeatability (2σ) | 20 to 65 Hz, AC/DC 10% sine wave | 0.3 % | ||
| XYZ *6 | Measurement luminance range*7 | 1 to 20,000 cd/m2 | ||
| Measurement target (Flicker frequency) | 0.25 to 200 Hz | |||
| Accuracy | 30 Hz, AC/DC 10% sine wave | ± 1.5 % | ||
| 60 Hz, AC/DC 10% sine wave | ± 2.2 % | |||
| Repeatability (2σ) | 20 to 65 Hz, AC/DC 10% sine wave | 1.6 % | ||
| Flicker (JEITA) | Flicker *6 | Measurement luminance range*7 | 1 to 20,000 cd/m2 | |
| Measurement target (Flicker frequency) | 0.42 to 65 Hz | |||
| Accuracy | 30 Hz, AC/DC 4% sine wave | ± 0.35 dB | ||
| 30 Hz, AC/DC 1.2% sine wave | ± 0.35 dB | |||
| Repeatability (2σ) | 30 Hz, AC/DC 4% sine wave | 0.1 dB | ||
| 30 Hz, AC/DC 1.2% sine wave | 0.3 dB | |||
| XYZ *6 | Measurement luminance range*7 | 1 to 14,000 cd/m2 | ||
| Measurement target (Flicker frequency)*8 | 0.42 to 200 Hz | |||
| Accuracy | 30 Hz, AC/DC 4% sine wave | ± 0.35 dB | ||
| 30 Hz, AC/DC 1.2% sine wave | ± 0.35 dB | |||
| Repeatability (2σ) | 30 Hz, AC/DC 4% sine wave | 0.4 dB | ||
| 30 Hz, AC/DC 1.2% sine wave | 1.4 dB | |||
| Waveform | Flicker *6 | Measurement luminance range*7 | 0.2 to 20,000 cd/m2 | |
| Sampling frequency | 200 kHz Changeable | |||
| Repeatability (2σ) | Lv: Measurement minimum luminance, fs: 3 kHz, fc: 1 kHz | 1.8% | ||
| XYZ *6 | Measurement luminance range*7 | 0.2 to 19,000 cd/m2 | ||
| Sampling frequency | 3 kHz Changeable | |||
| Repeatability (2σ) | Lv: Measurement minimum luminance | 13% | ||
| Lv: 1 cd/m2 | 2.8% | |||
| VRR-Flicker | Flicker | Measurement luminance range*7 | 1 to 20,000 cd/m2 | |
| Sampling frequency*8 | 200 kHz Changeable | |||
| Measurement target (Flicker frequency)*8 | 0.01 to 100 k [Hz] | |||
| Accuracy | 1 to 120 Hz, AC/DC 10% sine wave | ± 0.3 % | ||
| Repeatability (2σ) | 1 to 120 Hz, AC/DC 10% sine wave | 0.3 % | ||
| Accuracy guaranteed measurement speed *4 | Lvxy | AUTO | 1 time/sec (> 0.0002 cd/m2) | |
| 5 times/sec (> 0.02 cd/m2) | ||||
| 20 times/sec (> 0.25 cd/m2) | ||||
| Flicker (Contrast) | 20 times/sec | |||
| Flicker (JEITA/VESA) | 0.5 times/sec (at 1 HzPitch), 2.5 times/sec (at 10 HzPitch) | |||
| VRR-Flicker | Sampling frequency: 3 kHz | 0.7 times/sec (at 1s Obs.) | ||
| Measurement target (Vertical synchronization frequency) | 0.5 to 240 Hz (luminance and chromaticity) | |||
| Power supply | DC 5 V (USB bus power or RS communication connector) | |||
| Operating temperature/humidity range*5 | 10 to 35°C, RH 85% or less, no condensation | |||
| Storage temperature/humidity range | 0 to 45°C, RH 85% or less (at 35°C), no condensation | |||
*1: Measured under Konica Minolta’s standard light source (6,500 K).
*2: Luminance for monochrome is measured when reading of luminance for white is 100 cd/m2.
*3: Temperature 23°C/± 2°C, relative humidity 40 % ± 10 %
*4: In NTSC [DOUBLE FRAME] synchronization mode using USB with one probe. Measured using a Konica Minolta-designated PC (with PC and probe directly connected, using the supplied measurement software).
*5: Reading fluctuation (compared to reference reading at 23°C, 40 % RH): Luminance: ± 2% for white; Chromaticity (at 100 cd/m2):
± 0.002 for white, ± 0.003 for monochrome
*6: “Flicker” and “XYZ” are mode names for PC Software CA-S40.
*7: Measured under Konica Minolta’s standard light source (constant light). If the luminance momentarily greatly exceeds the upper limit, such as with a PWM light source with a small duty cycle, luminances below the upper limit may be shown as too high.
*8: The listed values are for use with CA-S40 or CA-SDK2.
* Unless otherwise specified, specifications are given for conditions established by Konica Minolta.