CA-2500 2D Color Analyzer
Click to Enlarge Thumbnails
The CA-2500 2D Color Analyzer is ideal for the evaluation and inspection of a variety of display technologies, such as smartphones and tablet PCs.
This instrument uses XYZ filters that closely match the CIE 1931 color-matching functions to provide luminance and chromaticity measurements that have high correlation with the spectral response of the human eye.
The low-luminance measurement range has been improved from 0.1 cd/m squared to 0.05 cd/m2. It is compact and lightweight which makes it easy to be set up anywhere. The service life measurement cycles have been increased to approximately 5 times to that of the CA-2000, which makes it applicable for use in the production area.
The advanced Data Management Software, CA-S25w, included as a standard accessory, provides advanced functionality and simple operation to make the entire measurement process easier. From measurement preparations such as focusing and positioning, to measurements of luminance and chromaticity and the evaluation of measurement results, it greatly streamlines the entire measurement process.
Existing Customer?
If you're looking for service support or help with calibration then complete a service request form and we'll get right back to you
Features
- XYZ filters provide high correlation with the spectral response of the human eye
- Interchangeable lenses for measurements of various subjects
- Comprehensive factor calibration
- Expanded low-luminance measurement range – minimum measurable luminance is 0.05 cd/m²
- Improved durability
- CA-S25w Advanced Data Management Software included as a standard accessory
- Luminance and chromaticity distribution measurements
- Multi-subject measurement capability
- Interchangeable lenses
Specifications
Model | CA-2500S | CA-2500W | CA-2500T | |||
---|---|---|---|---|---|---|
Light Receptor | CCD image sensor (monochrome) ; 2/3-inch ; Effective number of pixels : 1,000 x 1,000 pixels ; Equipped with XYZ filter (closely matches CIE 1931 color-matching function) and ND filter | |||||
Lens | Interchangeable Standard, wide, and telephoto lenses; low-magnification and high-magnification macro rings (for use with telephoto lens) | |||||
Measurement Points (Resolution) |
980 x 980 (490 x 490 or 196 x 196 selectable by using Data Management Software CA-S25w) | |||||
Color Indication Modes | XYZ, LVxy, LVu v , T” uv, Dominant wavelength, Excitation purity, LV contrast | |||||
Display Modes | Pseudocolor, Chromaticity diagram, Spot, Cross section, Color Difference | |||||
Measurment Sizes (length per side of square) |
Standard lens | Wide lens | Telephoto lens | With low-manification macro ring | With high-manification macro ring | |
Approx. 98 mm or more (depending on the distance) | Approx. 145 mm or more (depending on the distance) | Approx. 115 mm or more (depending on the distance) | Approx. 57mm (Fixed) | Approx. 27mm (Fixed) | ||
Measurable Size for Typical Measurement Distance (size/distance) |
||||||
98mm / 250 mm Approx. | 145mm / 200 mm Approx. | 115mm / 900 mm Approx. | 57mm / 500 mm Approx. (Fixed) | 27mm / 300 mm Approx. (Fixed) | ||
210mm / 500 mm Approx. | 410mm / 500 mm Approx. | 275mm / 2,000 mm Approx. | ||||
440mm / 1,000 mm Approx. | 850mm / 1,000 mm Approx. | 420mm / 3,000 mm Approx. | ||||
890mm / 2,000 mm Approx. | 1,770mm / 2,000 mm Approx. | |||||
Measurable Luminance Range (including ND filter use) |
0.05 – 100,000 cd/m2 | 0.05 – 100,000 cd/m2 | 0.25 – 100,000 cd/m2 | 0.25 – 100,000 cd/m2 | 0.5 – 100,000 cd/m2 | |
Measurement Time | Single : Approx. 5 sec. or more; 4-time integration : Approx. 6 sec. or more; 16-time integration: Approx. 10 sec. or more; 64-time integration : Approx. 25 sec. or more; 256-time integration : Approx. 80 sec. or more | |||||
Accuracy | Luminance | +-3% | +-3% | +_3% | +-3% | +-3% |
Chromaticity | +-0.005 | +-0.005 | +-0.005 | +-0.005 | +-0.005 | |
Temperature/Humidity Drift (within the operating temperature/ humidity range) Luminance: +-2% of change compared to reference temperature and relative humidity of 23°C and 40% Chromaticity: +-0.004 of change compared to reference temperature and relative humidity of 23°C and 40% |
||||||
Repeatability | Luminance | 0.5% | 0.5% | 0.5% | 0.5% | 0.5% |
Chromaticity | 0.001 | 0.001 | 0.001 | 0.001 | 0.001 | |
Inter-Point Error | Luminance | +-2% | +-2% | +-2% | +-2% | +-2% |
Chromaticity | +-0.002 | +-0.002 | +-0.002 | +-0.002 | +-0.002 | |
Luminance | +-3% | +-3% | +-3% | +-3% | +-3% | |
Chromaticity | +-0.003 | +-0.003 | +-0.003 | +-0.003 | +-0.003 | |
Other Functions | Measurement sync (Synchronization frequency selectable), User calibration Integration function | |||||
Interface | USB 2.0 or higher | |||||
Operating Temperature and Humidity Range | 10-30°C, Relative humidity 70% or less/No condensation | |||||
Storage Temperature and Humidity Range | 0-30°C, Relative humidity 70% or less/No condensation, 30-35°C, Relative humidity 55% or less/No condensation | |||||
Size | Body only | 160 (W) x 164 (H) X 192 (D) mm (Height including handle: 211 mm) | ||||
When lens and lens hood are attached | 223 (D) mm | 219 (D) mm | 224 (D) mm | 230 (D) mm | 237 (D) mm | |
Weight | 3.5 kg approx. (when standard lens and lens hood are attached) | |||||
Power Source | AC Adapter 100-240 V ~ , 1.2 A, 50-60 Hz |